Technical Support

Vacuum Pump Fault Codes

Enter a warning code or keyword to find its meaning and suggested actions.

Enter the warning code shown on your equipment (such as WARNING 101), or select a pump model or series to browse its codes.

356 results

Warning W16 ADP TEMP LOW ALCATEL ADP Series
Fault D 15 ADP TEMP. HIGH ALCATEL ADP Series
Fault D15 ADP TEMP. HIGH ALCATEL ADP Series
Fault D15 ADP TEMP. HIGH ALCATEL ADP Series
Warning W01 EXHAUST PRESSURE ALCATEL ADP Series
Fault D01 EXHAUST PRESSURE ALCATEL ADP Series
Warning W32 ADP MAINT. W31 ADP LP MAINT. W30 EXHAUST MAINT. W29 ROOTS MAINT. W28 LOAD LOCK MAINT. ALCATEL ADP Series
Warning W11 INLET VALVE There is no isolating valve at inlet ALCATEL ADP Series
Warning W11 INLET VALVE There is an isolating valve at inlet ALCATEL ADP Series
Warning W02 AUX. TEMPERATURE “AUX TEMPERATURE” input not used ALCATEL ADP Series
Warning W02 AUX. TEMPERATURE “AUX TEMPERATURE” input is used ALCATEL ADP Series
Warning W07 SPEED CONTROL ALCATEL ADP Series
Warning / Fault W18 LOAD LOCK POMPE LI1 and LI3 logic inputs are not used to monitor a LL pump ALCATEL ADP Series
Warning / Fault W05/D05 LOGIC INPUT 1 or W06/D06 LOGIC INPUT 2 or W12/D12 LOGIC INPUT 3 ALCATEL ADP Series
Warning / Fault W04/D04 ANALOG INPUT ALCATEL ADP Series
Bad vacuum or no vacuum ALCATEL ADP Series
WARN: WATER FLOW LOW 警告:水流量低 CẢNH BÁO: NƯỚC NỔI THẤP EBARA ESA Series
Water flow is reduced.
水流量減少。
Lưu lượng nước giảm.
檢查項目:Coupler is disconnected.
耦合器已斷開連接。
Coupler bị ngắt k ế t nối.

糾正措施:Connect coupler.
連接耦合器。
K ế t nối bộ ghép.
WARN: WATER FLOW LOW 警告:水流量低 CẢNH BÁO: NƯỚC NỔI THẤP EBARA ESA Series
Water flow is reduced.
水流量減少。
Lưu lượng nước giảm.
檢查項目:Pressure is not sufficient.
壓力不夠。
Áp lực không đủ.

糾正措施:Apply sufficient pressure.
施加足夠的壓力。
Áp dụng đủ áp lực.
WARN: WATER FLOW LOW 警告:水流量低 CẢNH BÁO: NƯỚC NỔI THẤP EBARA ESA Series
Water flow is reduced.
水流量減少。
Lưu lượng nước giảm.
檢查項目:Root valve is closed.
根閥關閉。
Van gốc được đóng lại.

糾正措施:Open valve.
打開閥門。
Mở van.
WARN: WATER FLOW LOW 警告:水流量低 CẢNH BÁO: NƯỚC NỔI THẤP EBARA ESA Series
Water flow is reduced.
水流量減少。
Lưu lượng nước giảm.
檢查項目:Water pipe is clogged.
水管堵塞。
Ống nước bị tắc.

糾正措施:Clean or replace piping.
清潔或更換管道。
Làm sạch hoặc thay th ế đường ống.